Controls Lab OnLine


______UTC______
Assignment 9



Web Assignment 9
Root Locus
1. You got here. Good going! Today, it is root locus modeling to design a proportional feedback controller.
2. We already have an Excel model built to do this. Download the model and load it into Excel.
3. Click on

Root Locus plot for P-only Feedback Model for FOPDT System

4. Fill in the parameters for your system: system gain (K), dead time (to) and first-order time constant (tau). Then look at the graph.

The graph should look something like this:
Excel RL-PO-FOPDT Graph

If the Root Locus does not cross the y-axis, then you need to extend the values of Kc (in column 1) by either making larger intervals between the individualt values or by dragging the cell formulas to more cells.

5. Find the value of Kc that is at the "breakaway" point. This is Kc for critical decay.
Find the value of Kc that is at the "ultimate" point. This is Kcu
Find the value of Kc that gives an imaginary value = 4.8 times the real value (This is shown in column "F" in the spread sheet). This is Kc for quarter decay.
6. Send an e-mail (report) within the next few days. (Click on "report" to get instructions.)

**** CONTINUOUS IMPROVEMENT ***

For suggestions and feedback,

contact Jim Henry - Lab-Master Send E-Mail to Jim Henry
Last revised 3 November 1997

Home Page of The University of Tennessee at Chattanooga Lab
Front
Door
Web-Manual
Table of
Contents