The University of Tennessee at Chattanooga

Engineering 329

  

 

Flow Control System

by

"Name" Group

 

Wade Atkinson

James Vansteenburg

Vic Flanagan

==============================================================

The Flow Lab.......

 

• The apparatus......

• The control system......

• The SSOC......

• FOPDT model vs. Flow System........

==============================================================

 

 

System input:

% Of motor speed from computer. (%)

 

System Output:

Water flow reading from flow meter.(lbm/min)

 

Operating Range:

Due to dependence of pressure for the solenoid valve to work properly, our focus will be above 50% motor speed up to 90% motor speed.

==============================================================

FOPDT

 

F irst

O rder

P lus

D ead

T ime

 

Why is this important?

Most controller-tuning formulas are

based on this model.

 

==============================================================

 

The Results: ( +.01 unless noted )

==============================================================

Final Results:

Fathom Group

FOPDT step response results

 

Gain 0.33 + 0.01

Dead Time 0.32 + 0.14

Time Constant 0.58 + 0.25

==============================================================